Export citation

Export citation

Choose format for download:

Download Citation

    Electron decoherence in cylindrical holes and circular apertures

    Cruz I. Velasco1,* and F. Javier García de Abajo1,2,†

    • *Contact author: cruzignaciovelasco@gmail.com
    • †Contact author: javier.garciadeabajo@nanophotonics.es

    Phys. Rev. B 114, 225402 – Published 5 October, 2026

    DOI: https://doi.org/10.1103/dxbg-9bs6

    Abstract

    The coherence of free electrons sets fundamental limits on the resolution and contrast of phase-sensitive electron microscopy because coherence is lost whenever the electron leaves a distinguishing excitation in its environment. We develop a quantitative theory of fast-electron decoherence in two canonical geometries: a cylindrical hole drilled through a realistic metal and a circular aperture in a thin, perfectly conducting film. By combining an electromagnetic Green-tensor formulation with the fluctuation-dissipation theorem while fully retaining retardation, we obtain the decoherence probability and elastic phase as functions of the electron trajectory, temperature, and material response. For the cylindrical hole, we obtain a closed-form, azimuthally resolved expression that separates the dependencies on path position, temperature, and conductivity. In the high-conductivity and high-temperature limits, this result reduces to a universal expression that is linear in temperature and independent of both conductivity and electron velocity. For the circular aperture, which we solve using a cylindrical-wave modal expansion, the energy-loss probability diverges as 1/ω at low frequency, whereas the decoherence probability remains finite and reaches a maximum when the aperture radius is comparable to the relevant electromagnetic wavelength. Because the interaction is spatially localized, aperture-induced decoherence is generally weaker than that produced by a cylindrical hole, except for sufficiently large apertures at high temperature. Finally, we show that, for sufficiently large holes, decoherence can dominate the spatial broadening of a focused electron probe and must therefore be incorporated into the design of coherent electron-beam instruments.

    Physics Subject Headings (PhySH)

    Authorization Required

    We need you to provide your credentials before accessing this content.

    Supplemental Material (Subscription Required)

    References (Subscription Required)

    Outline

    Information

    Sign In to Your Journals Account

    Filter

    Filter

    Article Lookup

    Enter a citation