    Systematic analysis of shielding properties of magnetically shielded rooms

    Zhiyin Sun and Liyi Li*

    Allard Schnabel† and Tianhao Liu

    Peter Fierlinger

    • School of Electrical Engineering and Automation, Laboratory for Space Environment and Physical Sciences, Harbin Institute of Technology, Harbin, 15001, China

    • *Contact author: liliyi@hit.edu.cn
    • †Contact author: allard.schnabel@web.de

    Phys. Rev. Applied 26, 044043 – Published 15 October, 2026

    DOI: https://doi.org/10.1103/1d7n-ymgr

    This article was published on 15 October, 2026. Please update your links.

    Abstract

    Enclosures made of highly permeable and highly conductive materials are used as passive shields to reduce the static magnetic field and magnetic disturbances for fundamental physics experiments and biomedical diagnostics. The two most significant specifications of a magnetic shield are the shielding factor (SF) and the residual static magnetic field. We present an alternative strategy to improve the prediction of shielding factors, taking into account the influence of gaps and overlaps in the real complex structure, which reduce the shielding properties of the magnetically shielded rooms (MSRs) in comparison to virgin shielding material. The air gap δ between the sheets turns out to be the most critical parameter with respect to the shielding factor. By using a reasonable value δ, it is possible to theoretically estimate a nonlinear equivalent permeability of the shielding wall structure, which leads to a realistic prediction of the frequency-dependent shielding factor up to about 20 Hz. The residual static field distribution inside the shield is hard to predict because it depends on the magnetic history of the shielding material. A reproducible residual field stable in time can only be obtained by a demagnetization process. The presented simulation of the complete demagnetization process, considering the complex structure of an MSR with material gaps, overlaps, feedthrough openings, and different arrangements of the degaussing coils, is able to predict the residual field distribution inside MSRs for the environmental field around the chamber. The prediction of the limit obtainable by degaussing can explain the surprisingly low magnitude of the residual field observed and reproduced inside a three-layer MSR.

    Physics Subject Headings (PhySH)

    Authorization Required

    We need you to provide your credentials before accessing this content.

    References (Subscription Required)

    Outline

    Information

    Sign In to Your Journals Account

    Filter

    Filter

    Article Lookup

    Enter a citation