- Open Access
Evaluation of coincidence time resolution in a liquid xenon detector with silicon photomultipliers
Phys. Rev. Research 7, 033089 – Published 24 July, 2025
DOI: https://doi.org/10.1103/vy9h-twqf
Abstract
This work explores the combination of liquid xenon as a scintillating medium and silicon photomultipliers as a readout in Positron Emission Tomography (PET) for enhanced Time-Of-Flight resolution. We present the results of our first prototype optimized to maximize light collection using high photodetection efficiency (PDE), VUV-sensitive sensors and to minimize time fluctuations. We report a coincidence time resolution of ps FWHM, obtained using a calibration source. This result is competitive with the current state-of-the-art PET scanners and represents a significant step forward in the development of liquid xenon as a viable alternative to conventional scintillators in PET technology.
Physics Subject Headings (PhySH)
Article Text
References (39)
- T. Tomitani, Image reconstruction and noise evaluation in photon time-of-flight assisted positron emission tomography, IEEE Trans. Nucl. Sci. 28, 4581 (1981).
- N. A. Mullani et al., Feasability of time-of-flight reconstruction in positron emission tomography, J. Nucl. Med. 21, 1095 (1980).
- M. M. Ter-Pogossian et al., Super PETT I: A positron emission tomograph utilizing photon time-of-flight information, IEEE Trans. Med. Imaging 1, 179 (1982).
- R. Gariod et al., The LETI positron tomograph architecture and time of flight improvements, in Proceedings of the Workshop on Time of Flight Tomography (IEEE, Washington University, 1982), pp. 25–29.
- W. H. Wong et al., Performance characteristics of the University of Texas TOFPET-I PET camera, J. Nucl. Med. 25, 05 (1986).
- T. K. Lewellen et al., Performance measurements of the SP3000/UW time-of-flight positron emission tomograph, IEEE Trans. Nucl. Sci. 35, 665 (1988).
- B. Mazoyer et al., Physical characteristics of TTV03, a new high spatial resolution time-of-flight positron tomograph, IEEE Trans. Nucl. Sci. 37, 778 (1990).
- K. Ishii et al., High resolution time-of-flight positron emission tomograph, Rev. Sci. Instrum. 61, 3755 (1990).
- T. K. Lewellen, Time-of-flight PET, Semin. Nucl. Med. 28, 268 (1998).
- LYSO(Ce) properties, https://www.advatech-uk.co.uk/lyso_ce.html.
- LSO(Ce) properties, https://www.advatech-uk.co.uk/lso_ce.html.
- S. Surti et al., Performance of Philips Gemini TF PET/CT scanner with special consideration for its time-of-flight imaging capabilities, J. Nucl. Med. 48, 471 (2007).
- B. W. Jakoby et al., Physical and clinical performance of the mCT time-of-flight PET/CT scanner, Phys. Med. Biol. 56, 2375 (2011).
- R. Badawi et al., First human imaging studies with the EXPLORER total-body PET scanner, J. Nucl. Med. 60, 299 (2019).
- J. van Sluis et al., Performance characteristics of the digital biograph vision PET/CT system, J. Nucl. Med. 60, 1031 (2019).
- T. Pan et al., Performance evaluation of the 5-ring GE discovery MI PET/CT system using the national electrical manufacturers association NU 2-2012 standard, Med. Phys. 46, 3025 (2019).
- V. Chepel and H. Araujo, Liquid noble gas detectors for low energy particle physics, J. Instrum. 8, R04001 (2013).
- S. Kubota, M. Hishida, M. Suzuki, and J. Ruan, Dynamical behaviour of free electrons in the recombination process in liquid argon, krypton and xenon, Phys. Rev. B 20, 3486 (1979).
- E. Hogenbirk et al., Field dependence of electronic recoil signals in a dual-phase liquid xenon time projection chamber, J. Instrum. 13, P10031 (2018).
- V. Chepel, M. Lopes, V. Solovov, R. Marques, and A. J. P. L. Policarpo, Development of liquid xenon detectors for medical imaging, in Technique and Application of Xenon Detectors (World Scientific Publishing Co. Pte. Ltd., 2002), pp. 28–40.
- A. Phunpueok, W. Chewpraditkul, V. Thongpool, and D. Aphairaj, Comparison of photofraction for LuYAP:Ce, LYSO:Ce and BGO crystals in gamma ray detection, in Proceedings of the 15th Internacional Conference of Internacional Academy of Physical Science (Rajamangala University of Technology Thanyaburi, Faculty of Sciences and Technology, 2014).
- L. Lavoie, Liquid xenon scintillators for imaging of positron emitters, Med. Phys. 3, 283 (1976).
- V. Chepel et al., The liquid xenon detector for PET: Recent results, IEEE Trans. Nucl. Sci. 46, 1038 (1999).
- T. Doke, J. Kikuchi, and F. Nishikido, Time-of-flight positron emission tomography using liquid xenon scintillation, Nucl. Instrum. Methods Phys. Res. A 569, 863 (2006).
- V. N. Solovov, A. Hitachi, V. Chepel, M. I. Lopes, R. Ferreira Marques, and A. J. P. L. Policarpo, Detection of scintillation light of liquid xenon with a LAAPD, Nucl. Instrum. Methods Phys. Res. A 488, 572 (2002).
- J. J. Gómez-Cadenas, J. M. Benlloch-Rodríguez, P. Ferrario, F. Monrabal, J. Rodríguez, and J. F. Toledo, Investigation of the coincidence resolving time performance of a PET scanner based on liquid xenon: A Monte Carlo study, J. Instrum. 11, P09011 (2016).
- J. J. Gómez-Cadenas, J. M. Benlloch-Rodríguez, and P. Ferrario, Monte Carlo study of the coincidence resolving time of a liquid xenon PET scanner, using Cherenkov radiation, J. Instrum. 12, P08023 (2017).
- J. Renner et al., Monte Carlo characterization of PETALO, a full-body liquid xenon-based PET detector, J. Instrum. 17, P05044 (2022).
- A. Baldini et al., Absorption of scintillation light in a 100 l liquid xenon γ-ray detector and expected detector performance, Nucl. Instrum. Methods Phys. Res. A 545, 753 (2005).
- D. Akerib et al., Technical results from the surface run of the LUX dark matter experiment, Astropart. Phys. 45, 34 (2013).
- M. Yamashita et al., Scintillation response of liquid Xe surrounded by PTFE reflector for gamma rays, Nucl. Instrum. Methods Phys. Res. A 535, 692 (2004).
- D. Cichon, G. Eurin, F. Jörg, T. Marrodán Undagoitia, and N. Rupp, Transmission of xenon scintillation light through PTFE, J. Instrum. 15, P09010 (2020).
- V. Herrero-Bosch et al., PETALO read-out: A novel approach for data acquisition systems in PET applications, in 2018 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) (IEEE Medical Imaging Conference 2018, Sidney, Australia, 2018).
- A. di Francesco et al., TOFPET2: A high-performance ASIC for time and amplitude measurements of SiPM signals in time-of-flight applications, J. Instrum. 11, C03042 (2016).
- TOFPET 2C/D SiPM readout ASIC, PETsys Electronics, 29, Revision 13, https://www.petsyselectronics.com/web/website/documentation/TOFPET2%20Downloads/Documentation/PETsys%20TOFPET%202C%20ASIC%20-%20Datasheet%20(rev%2018).pdf.
- V. Nadig, M. Yusopova, H. Radermacher, D. Schug, B. Weissler, V. Schulz, and S. Gundacker, A Comprehensive study on the timing limits of the TOFPET2 ASIC and on approaches for improvements, IEEE Trans. Radiat. Plasma Med. Sci. 6, 893 (2022).
- Vereos PET/CT, https://www.usa.philips.com/healthcare/product/HC882446/vereos-digital-petct-proven-accuracy-inspires-confidence.
- S. Gundacker, A. Knapitsch, E. Auffray, P. Jarron, T. Meyer, and P. Lecoq, Time resolution deterioration with increasing crystal length in a TOF-PET system, Nucl. Instrum. Methods Phys. Res. A 737, 92 (2014).
- M. S. Brown, S. Gundacker, A. Taylor, C. Tummeltshammer, E. Auffray, P. Lecoq, and I. Papakonstantinou, Influence of depth of interaction upon the performance of scintillator detectors, PLoS ONE 9, e98177 (2014).