It is not necessary to obtain permission to reuse this article or its components as it is available under the terms of the Creative Commons Attribution 4.0 International license. This license permits unrestricted use, distribution, and reproduction in any medium, provided attribution to the author(s) and the published article's title, journal citation, and DOI are maintained. Please note that some figures may have been included with permission from other third parties. It is your responsibility to obtain the proper permission from the rights holder directly for these figures.

Export citation

Export citation

Choose format for download:

Download Citation
  • Open Access

Measurement of the scintillation resolution in liquid xenon and its impact for future segmented calorimeters

C. Romo-Luque1,*, N. Salor-Iguiñiz2,1,†, J. M. Benlloch-Rodríguez2, R. Esteve3, R. J. Aliaga4, V. Álvarez3, F. Ballester3, R. Gadea3, J. Generowicz5 et al.

A. Laing5, A. Martínez1, F. Monrabal2,6, M. Querol1, M. Rappaport7, J. Rodríguez3, J. Rodríguez-Ponce1, S. Teruel-Pardo1, J. F. Toledo3, R. Torres-Curado3, P. Ferrario2,6,‡, V. Herrero3, and J. J. Gómez-Cadenas2,6

  • *Now at Los Alamos National Laboratory, USA.
  • †Contact author: nerea.salor@dipc.org
  • ‡Also at Instituto de Física Corpuscular, Spain; On leave.

Phys. Rev. Research 8, 023138 – Published 11 May, 2026

DOI: https://doi.org/10.1103/jycz-rqbj

Abstract

We report on a measurement of the energy resolution that can be attained in liquid xenon when recording only the scintillation light. Our setup is optimized to maximize light collection and uses state-of-the-art, high-PDE (photodetection efficiency), VUV-sensitive silicon photomultipliers. We find a value of 3.7%±0.4% at 511 keV, once saturation effects are corrected for, a result close to the Poissonian resolution that we expect in our setup (2.8%±0.4% at 511 keV). Our results in the intrinsic resolution (2.3%±0.8%) are compatible, within errors, at 511 keV, with those found by theoretical estimations that have been standing for the last 20 years, 1.8%. Our work opens possibilities for apparatus based on liquid xenon and using scintillation only. In particular, it suggests that modular scintillation detectors using liquid xenon can be very competitive as building blocks in segmented calorimeters, with applications to Positron Emission Tomography technology.

View figure in article

Physics Subject Headings (PhySH)

Article Text

References (51)

  1. NaI(Tl) properties, https://www.advatech-uk.co.uk/nai_tl.html.
  2. CsI(Tl) properties, https://www.advatech-uk.co.uk/csi_tl.html.
  3. LYSO(Ce) properties, https://www.advatech-uk.co.uk/lyso_ce.html.
  4. BGO properties, https://www.advatech-uk.co.uk/bgo.html.
  5. M. Yeh and R.-Y. Zhu, Materials for future calorimeters, arXiv:2203.07154.
  6. S. Vandenberghe, P. Moskal, and J. Karp, State of the art in total body PET, Eur. J. Nucl. Med. Mol. Imaging Phys. 7, 35 (2020).
  7. V. Westerwoudt, M. Conti, and L. Eriksson, Advantages of improved time resolution for TOF PET at very low statistics, IEEE Trans. Nucl. Sci. 61, 126 (2014).
  8. M. Conti and B. Bendriem, The new opportunities for high time resolution clinical TOF PET, Clin. Transl. Imaging 7, 139 (2019).
  9. S. R. Cherry et al., Total-body PET: Maximizing sensitivity to create new opportunities for clinical research and patient care, J. Nucl. Med. 59, 3 (2018).
  10. R. D. Badawi et al., First human imaging studies with the EXPLORER total-body PET scanner, J. Nucl. Med. 60, 299 (2019).
  11. E. Aprile and T. Doke, Liquid xenon detectors for particle physics and astrophysics, Rev. Mod. Phys. 82, 2053 (2010).
  12. K. Fujii et al., High-accuracy measurement of the emission spectrum of liquid xenon in the vacuum ultraviolet region, Nucl. Instrum. Methods Phys. Res. Sect. A 795, 293 (2015).
  13. V. Chepel and H. Araujo, Liquid noble gas detectors for low energy particle physics, J. Instrum. 8, R04001 (2013).
  14. S. Kubota, A. Nakamoto, T. Takahashi, T. Hamada, E. Shibamura, M. Miyajima, K. Masuda, and T. Doke, Recombination luminescence in liquid argon and in liquid xenon, Phys. Rev. B 17, 2762 (1978).
  15. E. Hogenbirk et al., Field dependence of electronic recoil signals in a dual-phase liquid xenon time projection chamber, J. Instrum. 13, P10031 (2018).
  16. G. Gallucci, The MEG liquid xenon calorimeter, J. Phys.: Conf. Ser. 160, 012011 (2009).
  17. G. Anton et al. (EXO-200 Collaboration), Search for neutrinoless double-β decay with the complete EXO-200 dataset, Phys. Rev. Lett. 123, 161802 (2019).
  18. E. Aprile et al., Energy resolution and linearity of XENON1T in the MeV energy range, Eur. Phys. J. C 80, 785 (2020).
  19. G. Adhikari et al., nEXO: Neutrinoless double beta decay search beyond 1028 year half-life sensitivity, J. Phys. G: Nucl. Part. Phys. 49, 015104 (2022).
  20. J. Aalbers et al., DARWIN: Towards the ultimate dark matter detector, J. Cosmol. Astropart. Phys. 11 (2016) 017.
  21. G. Pereira, C. Silva, and V. N. Solovov, Energy resolution of the LZ detector for high-energy electronic recoils, J. Instrum. 18, C04007 (2023).
  22. L. Lavoie, Liquid xenon scintillators for imaging of positron emitters, Med. Phys. 3, 283 (1976).
  23. V. Chepel et al., The liquid xenon detector for PET: Recent results, IEEE Trans. Nucl. Sci. 46, 1038 (1999).
  24. P. Crespo et al., Pulse processing for the PET liquid xenon multiwire ionisation chamber, IEEE Trans. Nucl. Sci. 47, 2119 (1999).
  25. T. Doke, J. Kikuchi, and F. Nishikido, Time-of-flight positron emission tomography using liquid xenon scintillation, Nucl. Instrum. Methods Phys. Res. Sect. A 569, 863 (2006).
  26. A. Miceli, Liquid xenon detectors for positron emission tomography, J. Phys.: Conf. Ser. 312, 062006 (2011).
  27. L. G. Manzano et al., XEMIS: A liquid xenon detector for medical imaging, Nucl. Instrum. Methods Phys. Res. Sect. A 787, 89 (2015).
  28. V. Chepel, M.I. Lopes, V. Solovov, R.Ferreira Marques, A.J.P.L. Policarpo, Development OF Liquid Xenon Detectors for Medical Imaging, Technique and Application of Xenon Detectors, (2003), pp. 28–40.
  29. J. J. Gomez-Cadenas et al., Investigation of the coincidence resolving time performance of a PET scanner based on liquid xenon: A Monte Carlo study, J. Instrum. 11, P09011 (2016).
  30. J. J. Gomez-Cadenas, J. M. Benlloch-Rodríguez, and P. Ferrario, Monte Carlo study of the coincidence resolving time of a liquid xenon PET scanner, using Cherenkov radiation, J. Instrum. 12, P08023 (2017).
  31. V. Herrero-Bosch et al., PETALO read-out: A novel approach for data acquisition systems in PET applications, in 2018 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) (IEEE Medical Imaging Conference, Sydney, Australia, 2018), pp. 1–4.
  32. J. Renner et al., Processing of Compton events in the PETALO readout system, in 2019 IEEE Nuclear Science Symposium (NSS) and Medical Imaging Conference (MIC) (IEEE, Manchester, United Kingdom, 2019), pp. 1–7.
  33. P. Ferrario et al., PETALO: Time-of-Flight PET with liquid xenon, in 2018 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) (IEEE Medical Imaging Conference, Sydney, Australia, 2018).
  34. J. Renner et al., Monte Carlo characterization of PETALO, a full-body liquid xenon-based PET detector, J. Instrum. 17, P05044 (2022).
  35. N. Salor-Iguiñiz et al., Evaluation of coincidence time resolution in a liquid xenon detector with silicon photomultipliers, Phys. Rev. Res. 7, 033089 (2025).
  36. T. Doke, R. Sawada, and H. Tawara, Non-proportionality of the scintillation yield in liquid xenon and its effect on the energy resolution for gamma-rays, in Technique and Application of Xenon Detectors (Japan, 2003), p. 17.
  37. M. Szydagis et al., Noble element simulation Technique v2.0 (v2.0.0), Zenodo (2018), https://zenodo.org/records/1314669.
  38. M. Yamashita et al., Scintillation response of liquid Xe surrounded by PTFE reflector for gamma rays, Nucl. Instrum. Methods Phys. Res. Sect. A 535, 692 (2004).
  39. G. Plante, E. Aprile, R. Budnik, B. Choi, K.-L. Giboni, L. W. Goetzke, R. F. Lang, K. E. Lim, and A. J. M. Fernandez, New measurement of the scintillation efficiency of low-energy nuclear recoils in liquid xenon, Phys. Rev. C 84, 045805 (2011).
  40. K. Ni et al., Gamma ray spectroscopy with scintillation light in liquid xenon, J. Instrum. 1, P09004 (2006).
  41. A. Baldini et al., Absorption of scintillation light in a 100l liquid xenon γ-ray detector and expected detector performance, Nucl. Instrum. Methods Phys. Res. Sect. A 545, 753 (2005).
  42. D. Akerib et al., Technical results from the surface run of the LUX dark matter experiment, Astropart. Phys. 45, 34 (2013).
  43. A. Di Francesco et al., TOFPET2: A high-performance ASIC for time and amplitude measurements of SiPM signals in time-of-flight applications, J. Instrum. 11, C03042 (2016).
  44. S. Agostinelli et al., Geant4—a simulation toolkit, Nucl. Instrum. Methods Phys. Res. Sect. A 506, 250 (2003).
  45. A. Baldini et al., Liquid xenon scintillation calorimetry and Xe optical properties, IEEE Trans. Dielect. Electr. Insul. 13, 547 (2006).
  46. V. Solovov et al., Measurement of the refractive index and attenuation length of liquid xenon for its scintillation light, Nucl. Instrum. Methods Phys. Res. Sect. A 516, 462 (2004).
  47. Linearity curve for Hamamatsu SiPMs, https://www.hamamatsu.com/eu/en/resources/interactive-tools/mppc-sipm-linearity.html.
  48. C. Silva et al., Reflectance of polytetrafluoroethylene for xenon scintillation light. J. Appl. Phys. 107, 064902 (2010).
  49. S. Kravitz et al., Measurements of angle-resolved reflectivity of PTFE in liquid xenon with IBEX, Eur. Phys. J. C 80, 262 (2020).
  50. D. S. Akerib et al. (LUX Collaboration), Calibration, event reconstruction, data analysis, and limit calculation for the LUX dark matter experiment, Phys. Rev. D 97, 102008 (2018).
  51. F. Neves et al., Measurement of the absolute reflectance of polytetrafluoroethylene (PTFE) immersed in liquid xenon, J. Instrum. 12, P01017 (2017).

Outline

Information

Sign In to Your Journals Account

Filter

Filter

Article Lookup

Enter a citation