Noninvasive magnetocardiography of a living rat based on a diamond quantum sensor

Ziyun Yu1,2, Yijin Xie3, Guodong Jin1,2, Yunbin Zhu1,2, Qi Zhang1,2, Fazhan Shi1,2,4, Fang-yan Wan5, Hongmei Luo5, Ai-hui Tang5,6 et al.

Xing Rong1,2,4,*

  • 1CAS Key Laboratory of Microscale Magnetic Resonance and School of Physical Sciences, University of Science and Technology of China, Hefei 230026, China
  • 2CAS Center for Excellence in Quantum Information and Quantum Physics, University of Science and Technology of China, Hefei 230026, China
  • 3Institute of Quantum Sensing and School of Physics, Zhejiang University, Hangzhou 310027, China
  • 4Hefei National Laboratory, University of Science and Technology of China, Hefei 230088, China
  • 5CAS Key Laboratory of Brain Function and Disease, Hefei National Laboratory for Physical Sciences at the Microscale, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei 230026, China
  • 6Institute of Artificial Intelligence, Hefei Comprehensive National Science Center, Hefei 230088, China

  • *Corresponding author: xrong@ustc.edu.cn

Phys. Rev. Applied 21, 064028 – Published 12 June, 2024

DOI: https://doi.org/10.1103/PhysRevApplied.21.064028

Abstract

Magnetocardiography (MCG) has emerged as a sensitive and precise method to diagnose cardiovascular diseases, providing more diagnostic information than traditional technology. However, the sensor limitations of conventional MCG systems, such as large size and cryogenic requirement, have hindered the widespread application and in-depth understanding of this technology. In this study, we present a high-sensitivity, room-temperature MCG system based on the negatively charged nitrogen-vacancy (N-V) centers in diamond. The magnetic cardiac signal of a living rat, characterized by an approximately 20-pT amplitude in the R wave, is successfully captured through noninvasive measurement using this innovative solid-state spin sensor. To detect these extremely weak biomagnetic signals, we utilize sensitivity-enhancing techniques such as magnetic flux concentration. These approaches have enabled us to simultaneously achieve a magnetometry sensitivity of 9pTHz−1/2 and a sensor scale of 5 mm. By extending the sensing scale of the N-V centers from cellular and molecular level to macroscopic level of living creatures, we have opened the future of solid-state quantum sensing technologies in clinical environments.