    Optomicrofluidic measurement of particle-encapsulated droplets

    Kanimozhi Kumaresan1,2, Thaipally Sujith2, Anil Prabhakar1,*, and Ashis Kumar Sen2,†

    • *Contact author: anil@ee.iitm.ac.in
    • †Contact author: ashis@iitm.ac.in

    Phys. Rev. Applied 25, 054069 – Published 27 May, 2026

    DOI: https://doi.org/10.1103/98dy-58q3

    Abstract

    Droplet microfluidics combined with optical detection has emerged as a transformative avenue for high-throughput single-cell assays. However, these platforms often suffer from limited sensitivity and signal heterogeneity due to intrinsic optical and geometric constraints. We investigate how key operating parameters influence the performance of a droplet-based optomicrofluidic system. Our experiments probe optical interactions between guided light and aqueous droplets encapsulating fluorescent particles flowing in an oil medium. Geometric optics simulations model light-droplet interaction, while florescence simulations quantify signal variation due to particle size and position. Experimentally, we observe two refracted optical signals: a droplet-refracted signal that scales with droplet diameter, and a particle-refracted signal arising from light interaction with encapsulated particles. Both experiments and simulations reveal that the particle-refracted signal is prominent when the particle-to-droplet size ratio Dp∗ is between 0.23 and 0.33, enabling label-free detection. Experiments also show that particles located near the droplet center (rp∗<0.4) exhibit a reduced angular dependence, producing more uniform fluorescence signals. Simulations indicate that the fluorescence intensity increases with Dp∗, with a strong rise from 0.33 to 0.5 and a more gradual increase up to 0.66. Further, simulations show that reducing the thickness of the oil layer consistently increases fluorescence by minimizing optical losses at the droplet/channel interface. Our results demonstrate that controlling Dp∗, particle position, and oil-layer thickness significantly increases fluorescence intensity and uniformity. These findings establish a quantitative and experimentally validated framework for optimizing droplet-based fluorescence detection, with potential applications in microflow cytometry and single-cell assays.

    Physics Subject Headings (PhySH)

    Authorization Required

    We need you to provide your credentials before accessing this content.

    Supplemental Material (Subscription Required)

    References (Subscription Required)

    Outline

    Information

    Sign In to Your Journals Account

    Filter

    Filter

    Article Lookup

    Enter a citation