- Open Access
Optimized permanent-magnet loops and arcs for improved field uniformity
Phys. Rev. Applied 26, 054045 – Published 16 November, 2026
DOI: https://doi.org/10.1103/8nkv-46hc
Abstract
Simple, low-cost, permanent magnet geometries are frequently used for field generation in cases where a constant high-strength magnetic field is required. This is the situation across many emerging quantum platforms, primarily for bias fields in quantum computing or nitrogen-vacancy centers. Finding optimal arrangements of primitive magnet geometries such as these can be difficult, often escalating in complexity, as further higher-order field harmonics are considered. This is further complicated by the need to adhere to strict system constraints, for instance, those implied by geometric or optical access requirements. Here we illustrate a method that encodes loop and arc magnet geometries into an analytical form, attaining solutions for the field harmonics produced by both axial and radial magnetizations for each form. These harmonic descriptions then form the basis of a numerical design procedure. Our approach facilitates solutions that improve fidelity of the target field by reducing error harmonic contributions while satisfying constraints on magnet position. This allows for considerations such as optical access or maximum system extents to be accounted for. To demonstrate this optimization procedure, we produce four system designs: two axially magnetized loops to produce a uniform axial field and two radially magnetized arcs, which, respectively, produce a radial-uniform and radial-gradient field. Their performance is then compared against standard designs, obtained from analytical solutions alone. In each case, when using our approach, the volume of field uniformity within 99% agreement of the target field increases by a minimum factor of 1.37. Designs generated by this procedure therefore enable improved field fidelity and reduce magnetic field-driven errors.
Physics Subject Headings (PhySH)
Article Text
References (47)
- J. Reichel, W. Hänsel, and T. W. Hänsch, Atomic micromanipulation with magnetic surface traps, Phys. Rev. Lett. 83, 3398 (1999).
- H. J. Metcalf and P. Van der Straten, Laser Cooling and Trapping (Springer Science & Business Media, New York, 1999).
- S. Gov, S. Shtrikman, and H. Thomas, Magnetic trapping of neutral particles: Classical and quantum-mechanical study of a Ioffe–Pritchard type trap, J. Appl. Phys. 87, 3989 (2000).
- T. Schönau, T. Scholtes, F. Wittkämper, A. Sekels, S. Hiebel, G. Oelsner, and R. Stolz, Optically pumped vector magnetometer using a strong bias magnetic field, Phys. Rev. Appl. 23, 024006 (2025).
- Z.-X. Meng, P.-Q. Yan, S.-Z. Wang, X.-J. Li, H.-B. Xue, and Y.-Y. Feng, Closed-loop dual-atom-interferometer inertial sensor with continuous cold atomic beams, Phys. Rev. Appl. 21, 034050 (2024).
- J. Wang, L. Zhou, R.-B. Li, M. Liu, and M.-S. Zhan, Cold atom interferometers and their applications in precision measurements, Front. Phys. China 4, 179 (2009).
- R. Geiger, A. Landragin, S. Merlet, and F. Pereira Dos Santos, High-accuracy inertial measurements with cold-atom sensors, AVS Quantum Sci. 2, 024702 (2020).
- B. Wu, Z. Wang, B. Cheng, Q. Wang, A. Xu, and Q. Lin, The investigation of a -level cold atom gravimeter for field applications, Metrologia 51, 452 (2014).
- A. Borna, J. Iivanainen, T. R. Carter, J. McKay, S. Taulu, J. Stephen, and P. D. D. Schwindt, Cross-axis projection error in optically pumped magnetometers and its implication for magnetoencephalography systems, NeuroImage 247, 118818 (2022).
- R. Dawson, M. S. Mrozowski, D. Hunter, C. O’Dwyer, E. Riis, P. Griffin, S. Ingleby et al., A triaxial vectorization technique for a single-beam zero-field atomic magnetometer to suppress cross-axis projection error, arXiv:2408.12994.
- R. Turner, A target field approach to optimal coil design, J. Phys. D 19, L147 (1986).
- F. Roméo and D. I. Hoult, Magnet field profiling: Analysis and correcting coil design, Magn. Reson. Med. 1, 44 (1984).
- M. Packer, P. J. Hobson, N. Holmes, J. Leggett, P. Glover, M. J. Brookes, R. Bowtell, and T. M. Fromhold, Optimal inverse design of magnetic field profiles in a magnetically shielded cylinder, Phys. Rev. Appl. 14, 054004 (2020).
- M. Packer, P. J. Hobson, N. Holmes, J. Leggett, P. Glover, M. J. Brookes, R. Bowtell, and T. M. Fromhold, Planar coil optimization in a magnetically shielded cylinder, Phys. Rev. Appl. 15, 064006 (2021).
- R. Zetter, A. J. Mäkinen, J. Iivanainen, K. C. J. Zevenhoven, R. J. Ilmoniemi, and L. Parkkonen, Magnetic field modeling with surface currents. Part II. Implementation and usage of bfieldtools, J. Appl. Phys. 128 063905 (2020).
- P. J. Hobson, N. L. Hardwicke, A. Davis, T. Smith, C. Morley, M. Packer, N. Holmes, M. A. Weil, M. Brookes, R. Bowtell, and M. Fromhold, Designing optimal loop, saddle, and ellipse-based magnetic coils by spherical harmonic mapping, arXiv:2305.00572.
- I. R. Hill, Y. B. Ovchinnikov, E. M. Bridge, E. A. Curtis, and P. Gill, Zeeman slowers for strontium based on permanent magnets, J. Phys. B 47, 075006 (2014).
- A. Parsagian and M. Kleinert, Designing and building a permanent magnet Zeeman slower for calcium atoms using a 3D printer, Am. J. Phys. 83, 892 (2015).
- J. M. D. Coey, Permanent magnet applications, J. Magn. Magn. Mater. 248, 441 (2002).
- F. Florio, G. Sinha, and R. Sundararaman, Designing high-accuracy permanent magnets for low-power magnetic resonance imaging, IEEE Trans. Magn. 54, 1 (2018).
- C. Hugon, F. D’Amico, G. Aubert, and D. Sakellariou, Design of arbitrarily homogeneous permanent magnet systems for NMR and MRI: Theory and experimental developments of a simple portable magnet, J. Magn. Reson. 205, 75 (2010).
- G. Moresi and R. Magin, Miniature permanent magnet for table-top NMR, Concepts Magn. Reson., Part B 19, 35 (2003).
- S. C. Scholten, A. J. Healey, I. O. Robertson, G. J. Abrahams, D. A. Broadway, and J.-P. Tetienne, Widefield quantum microscopy with nitrogen-vacancy centers in diamond: Strengths, limitations, and prospects, J. Appl. Phys. 130, 150902 (2021).
- S.-Y. Hou, G. Feng, Z. Wu, H. Zou, W. Shi, J. Zeng, C. Cao, S. Yu, Z. Sheng, X. Rao et al., SpinQ Gemini: A desktop quantum computing platform for education and research, Eur. Phys. J. Quantum Technol. 8, 1 (2021).
- I. Pogorelov, T. Feldker, C. D. Marciniak, L. Postler, G. Jacob, O. Krieglsteiner, V. Podlesnic, M. Meth, V. Negnevitsky, M. Stadler et al., Compact ion-trap quantum computing demonstrator, PRX Quantum 2, 020343 (2021).
- H. Aman and T. Plakhotnik, Accuracy in the measurement of magnetic fields using nitrogen-vacancy centers in nanodiamonds, J. Opt. Soc. Am. B 33, B19 (2016).
- N. P. de Leon, K. M. Itoh, D. Kim, K. K. Mehta, T. E. Northup, H. Paik, B. S. Palmer, N. Samarth, S. Sangtawesin, and D. W. Steuerman, Materials challenges and opportunities for quantum computing hardware, Science 372, eabb2823 (2021).
- T. Strohm, K. Wintersperger, F. Dommert, D. Basilewitsch, G. Reuber, A. Hoursanov, T. Ehmer, D. Vodola, and S. Luber, Ion-based quantum computing hardware: Performance and end-user perspective, arXiv:2405.11450.
- S. Noguchi, S. B. Kim, S. Hahn, and Y. Iwasa, Passive shimming by eliminating spherical harmonics coefficients of all magnetic field components generated by correction iron pieces, IEEE Trans. Magn. 50, 605 (2014).
- F. X. Li, J. P. Voccio, M. C. Ahn, S. Hahn, J. Bascuñán, and Y. Iwasa, An analytical approach towards passive ferromagnetic shimming design for a high-resolution nmr magnet, Supercond. Sci. Technol. 28, 075006 (2015).
- X. Zhu, H. Wang, H. Wang, Y. Li, and Y. Fang, A novel design method of passive shimming for 0.7-T biplanar superconducting mri magnet, IEEE Trans. Appl. Supercond. 26, 1 (2016).
- S. Noguchi, S. Kim, S. Hahn, and Y. Iwasa, Passive shimming by eliminating spherical harmonics coefficients of all magnetic field components generated by correction iron pieces, IEEE Trans. Magn. 50, 605 (2014).
- R. Schmied, D. Leibfried, R. J. C. Spreeuw, and S. Whitlock, Optimized magnetic lattices for ultracold atomic ensembles, New J. Phys. 12, 103029 (2010).
- Z. Y. Lu, G. S. Xu, D. H. Chen, L. Chen, X. Y. Zhang, M. Y. Ye, and B. N. Wan, Design of quasi-axisymmetric stellarators with variable-thickness perpendicular permanent magnets based on a two-step magnet design strategy, Nucl. Fusion 61, 106028 (2021).
- G. S. Xu, Z. Y. Lu, D. H. Chen, L. Chen, X. Y. Zhang, X. Q. Wu, M. Y. Ye, and B. N. Wan, Design of quasi-axisymmetric stellarators with varying-thickness permanent magnets based on fourier and surface magnetic charges method, Nucl. Fusion 61, 026025 (2021).
- P. J. Hobson, C. Morley, A. Davis, T. Smith, and M. Fromhold, Target-field design of surface permanent magnets, Phys. Rev. Appl. 22, 034015 (2024).
- W. Zhou, B. Han, J. Wang, D. Wu, F. Zhao, and N. Li, Design of uniform magnetic field coil by quasi-elliptic function fitting method with multiple optimizations in miniature atomic sensors, IEEE Trans. Ind. Electron. 69, 11755 (2022).
- J. L. Kirschvink, Uniform magnetic fields and double-wrapped coil systems: Improved techniques for the design of bioelectromagnetic experiments, Bioelectromagnetics 13, 401 (1992).
- H. Sanchez Lopez, Feng Liu, E. Weber, and S. Crozier, Passive shim design and a shimming approach for biplanar permanent magnetic resonance imaging magnets, IEEE Trans. Magn. 44, 394 (2008).
- J. Lee and J. Yoo, Topology optimization of the permanent magnet type MRI considering the magnetic field homogeneity, J. Magn. Magn. Mater. 322, 1651 (2010).
- K. Halbach, Design of permanent multipole magnets with oriented rare earth cobalt material, Nucl. Instrum. Methods 169, 1 (1980).
- S. Tewari, T. O’Reilly, and A. Webb, Improving the field homogeneity of fixed-and variable-diameter discrete Halbach magnet arrays for MRI via optimization of the angular magnetization distribution, J. Magn. Reson. 324, 106923 (2021).
- I. Rehberg and P. Blümler, Analytic approach to creating homogeneous fields with finite-size magnets, Phys. Rev. Appl. 23, 064029 (2025).
- J. D. Jackson, Classical Electrodynamics, 1st ed. (Wiley, New York, NY, 1962), pp. 156–158.
- J. M. Jackson, M. A. Brideson, L. K. Forbes, and S. Crozier, Tikhonov regularization approach for acoustic noise reduction in an asymmetric, self-shielded mri gradient coil, Concepts Magn. Reson., Part B 37, 167 (2010).
- H. Xu, S. M. Conolly, G. C. Scott, and A. Macovski, Homogeneous magnet design using linear programming, IEEE Trans. Magn. 36, 476 (2000).
- M. Packer, P. J. Hobson, A. Davis, N. Holmes, J. Leggett, P. Glover, N. L. Hardwicke, M. J. Brookes, R. Bowtell, and T. M. Fromhold, Magnetic field design in a cylindrical high-permeability shield: The combination of simple building blocks and a genetic algorithm, J. Appl. Phys. 131, 093902 (2022).