Export citation

Export citation

Choose format for download:

Download Citation

    Quantitative calibration of a traveling-wave parametric amplifier applied to an optomechanical platform

    Alexandre Delattre, Ilya Golokolenov, Richard Pedurand, Nicolas Roch, Arpit Ranadive*, Martina Esposito†, Luca Planat‡, Andrew Fefferman, and Eddy Collin§

    Xin Zhou

    Mika A. Sillanpää and Laure Mercier de Lépinay

    Andrew D. Armour and Jonas Glatthard

    • IEMN, Université Lille—CNRS UMR8520, Av. Henri Poincaré, Villeneuve d’Ascq 59650, France

    • School of Physics and Astronomy and Centre for the Mathematics and Theoretical Physics of Quantum Non-Equilibrium Systems, University of Nottingham, Nottingham NG7 2RD, United Kingdom

    • *Now at: Google QAI, Santa Barbara, California 93106, USA.
    • †Now at: CNR-SPIN Complesso di Monte S. Angelo, via Cintia, Napoli 80126, Italy.
    • ‡Now at: Silent Waves, 69–73 Rue Félix Esclangon, 38000 Grenoble, France.
    • §Contact author: Eddy.Collin@neel.cnrs.fr

    Phys. Rev. Applied 24, 054032 – Published 12 November, 2025

    DOI: https://doi.org/10.1103/1wgj-k7c5

    Abstract

    In the past decade, the microwave quantum electronics toolbox has been enriched with quantum limited detection devices such as traveling-wave parametric amplifiers (TWPAs). The extreme sensitivity that they provide is not only mandatory for some physics applications within quantum information processing, but is also the key element that will determine the detection limit of quantum sensing setups. In the framework of microwave optomechanical systems, an unprecedented range of small motions and forces is accessible, for which a specific quantitative calibration becomes necessary. We report on near quantum limited measurements performed with an aluminum drumhead mechanical device within the temperature range 4–400 mK. The whole setup is carefully calibrated, especially taking into account the power dependence of microwave absorption in the superconducting optomechanical cavity. This effect is commonly attributed to two-level systems (TLSs) present in the metal oxide. We demonstrate that a similar feature exists in the TWPA, and can be phenomenologically fitted with adapted expressions. If not taken into account, the error on the signal strength can be as large as a factor of about 2, which is unacceptable for quantitative experiments. The power and temperature dependence is studied over the full parameter range, leading to an absolute definition of the phonon population (i.e., Brownian-motion amplitude), with an uncertainty ±20% limited by sources of noise internal to the optomechanical element.

    Physics Subject Headings (PhySH)

    Authorization Required

    We need you to provide your credentials before accessing this content.

    References (Subscription Required)

    Outline

    Information

    Sign In to Your Journals Account

    Filter

    Filter

    Article Lookup

    Enter a citation