Reuse & Permissions

It is not necessary to obtain permission to reuse this article or its components as it is available under the terms of the Creative Commons Attribution 4.0 International license. This license permits unrestricted use, distribution, and reproduction in any medium, provided attribution to the author(s) and the published article's title, journal citation, and DOI are maintained. Please note that some figures may have been included with permission from other third parties. It is your responsibility to obtain the proper permission from the rights holder directly for these figures.

Export citation

Export citation

Choose format for download:

Download Citation
  • Featured in Physics
  • Open Access

Light Microscopy at Maximal Precision

Matthew Bierbaum, Brian D. Leahy, Alexander A. Alemi*, Itai Cohen, and James P. Sethna

  • Department of Physics, Cornell University, Ithaca, New York 14853, USA

  • *Work done while at Cornell; currently affiliated with Google Inc.

Phys. Rev. X 7, 041007 – Published 13 October, 2017

DOI: https://doi.org/10.1103/PhysRevX.7.041007

Abstract

Microscopy is the workhorse of the physical and life sciences, producing crisp images of everything from atoms to cells well beyond the capabilities of the human eye. However, the analysis of these images is frequently little more accurate than manual marking. Here, we revolutionize the analysis of microscopy images, extracting all the useful information theoretically contained in a complex microscope image. Using a generic, methodological approach, we extract the information by fitting experimental images with a detailed optical model of the microscope, a method we call parameter extraction from reconstructing images (PERI). As a proof of principle, we demonstrate this approach with a confocal image of colloidal spheres, improving measurements of particle positions and radii by 10–100 times over current methods and attaining the maximum possible accuracy. With this unprecedented accuracy, we measure nanometer-scale colloidal interactions in dense suspensions solely with light microscopy, a previously impossible feat. Our approach is generic and applicable to imaging methods from brightfield to electron microscopy, where we expect accuracies of 1 nm and 0.1 pm, respectively.

View figure in article

Physics Subject Headings (PhySH)

Focus

Modeling Imperfections Boosts Microscope Precision

Published 13 October, 2017

A theoretical model of light spreading and scattering improves precision of position and size measurements made with an optical microscope by as much as 100 times.

See more in Physics

Popular Summary

Article Text

Supplemental Material

References (52)

  1. E. Betzig, G. H. Patterson, R. Sougrat, O. W. Lindwasser, S. Olenych, J. S. Bonifacino, M. W. Davidson, J. Lippincott-Schwartz, and H. F. Hess, Imaging Intracellular Fluorescent Proteins at Nanometer Resolution, Science 313, 1642 (2006).
  2. M. J. Rust, M. Bates, and X. Zhuang, Sub-Diffraction-Limit Imaging by Stochastic Optical Reconstruction Microscopy (Storm), Nat. Methods 3, 793 (2006).
  3. S. W. Hell and J. Wichmann, Breaking the Diffraction Resolution Limit by Stimulated Emission: Stimulated-Emission-Depletion Fluorescence Microscopy, Opt. Lett. 19, 780 (1994).
  4. P. Kner, B. B. Chhun, E. R. Griffis, L. Winoto, and M. G. L. Gustafsson, Super-Resolution Video Microscopy of Live Cells by Structured Illumination, Nat. Methods 6, 339 (2009).
  5. B.-C. Chen, W. R. Legant, K. Wang, L. Shao, D. E. Milkie, M. W. Davidson, C. Janetopoulos, X. S. Wu, J. A. Hammer, Z. Liu et al., Lattice Light-Sheet Microscopy: Imaging Molecules to Embryos at High Spatiotemporal Resolution, Science 346, 1257998 (2014).
  6. S.-H. Lee and D. G. Grier, Holographic Microscopy of Holographically Trapped Three-Dimensional Structures, Opt. Express 15, 1505 (2007).
  7. J. Fung, K. E. Martin, R. W. Perry, D. M. Kaz, R. McGorty, and V. N. Manoharan, Measuring Translational, Rotational, and Vibrational Dynamics in Colloids with Digital Holographic Microscopy, Opt. Express 19, 8051 (2011).
  8. S. S. Rogers, T. A. Waigh, X. Zhao, and J. R. Lu, Precise Particle Tracking Against a Complicated Background: Polynomial Fitting with Gaussian Weight, Phys. Biol. 4, 220 (2007).
  9. R. Pathasarathy, Rapid, Accurate Particle Tracking by Calculation of Radial Symmetry Centers, Nat. Methods 9, 724 (2012).
  10. F. Grüll, M. Kirchgessner, R. Kaufmann, M. Hausmann, and U. Kebschull, Accelerating Image Analysis for Localization Microscopy with FPGAs, in 2011 International Conference on Field Programmable Logic and Applications (FPL), (IEEE, New York, 2011), pp. 1–5.
  11. S. M. Anthony and S. Granick, Image Analysis with Rapid and Accurate Two-Dimensional Gaussian Fitting, Langmuir 25, 8152 (2009).
  12. C. S. Smith, N. Joseph, B. Rieger, and K. A. Lidke, Fast, Single-Molecule Localization that Achieves Theoretically Minimum Uncertainty, Nat. Methods 7, 373 (2010).
  13. S. Andersson, Localization of a Fluorescent Source without Numerical Fitting, Opt. Express 16, 18714 (2008).
  14. Y. Gao and M. L. Kilfoil, Accurate Detection and Complete Tracking of Large Populations of Features in Three Dimensions, Opt. Express 17, 4685 (2009).
  15. P. J. Lu, M. Shutman, E. Sloutskin, and A. V. Butenko, Locating Particles Accurately in Microscope Images Requires Image-Processing Kernels to be Rotationally Symmetric, Opt. Express 21, 30755 (2013).
  16. M. E. Huber, N. C. Koshnick, H. Bluhm, L. J. Archuleta, T. Azua, P. G. Björnsson, B. W. Gardner, S. T. Halloran, E. A. Lucero, and K. A. Moler, Gradiometric Micro-Squid Susceptometer for Scanning Measurements of Mesoscopic Samples, Rev. Sci. Instrum. 79, 053704 (2008).
  17. K. C. Nowack, E. M. Spanton, M. Baenninger, M. König, J. R. Kirtley, B. Kalisky, C. Ames, P. Leubner, C. Brüne, H. Buhmann et al., Imaging Currents in HgTe Quantum Wells in the Quantum Spin Hall Regime, Nat. Mater. 12, 787 (2013).
  18. See Supplemental Material at http://link.aps.org/supplemental/10.1103/PhysRevX.7.041007 for an extended discussion of the generative model, computational details of its implementation, examination of additional complications such as Brownian motion, and comparison of PERI with other particle location methods.
  19. S. Ram, E. S. Ward, and R. J. Ober, Beyond Rayleigh’s Criterion: A Resolution Measure with Application to Single-Molecule Microscopy, Proc. Natl. Acad. Sci. U.S.A. 103, 4457 (2006).
  20. C. R. Rao, Information and Accuracy Attainable in the Estimation of Statistical Parameters, Bull. Calcutta Math. Soc. 37, 81 (1945).
  21. During the exposure of a recording camera, 3 nm is almost always less than a free colloidal particle’s Brownian motion. Nevertheless, we show in SM [18] (Sec. IV) that the particle’s mean position during the camera’s exposure is measurable to within 3 nm.

  22. K. Keville, E. Franses, and J. Caruthers, Preparation and Characterization of Monodisperse Polymer Microspheroids, J. Colloid Interface Sci. 144, 103 (1991).
  23. A. Mohraz and M. J. Solomon, Direct Visualization of Colloidal Rod Assembly by Confocal Microscopy, Langmuir 21, 5298 (2005).
  24. A. Kuijk, A. van Blaaderen, and A. Imhof, Synthesis of Monodisperse, Rodlike Silica Colloids with Tunable Aspect Ratio, J. Am. Chem. Soc. 133, 2346 (2011).
  25. S. Guttman, Z. Sapir, M. Schultz, A. V. Butenko, B. M. Ocko, M. Deutsch, and E. Sloutskin, How Faceted Liquid Droplets Grow Tails, Proc. Natl. Acad. Sci. U.S.A. 113, 493 (2016).
  26. S. Hell, G. Reiner, C. Cremer, and E. H. K. Stelzer, Aberrations in Confocal Fluorescence Microscopy Induced by Mismatches in Refractive Index, J. Microsc. 169, 391 (1993).
  27. T. D. Visser and S. H. Wiersma, Electromagnetic Description of Image Formation in Confocal Fluorescence Microscopy, J. Opt. Soc. Am. A 11, 599 (1994).
  28. B. Zhang, J. Zerubia, and J.-C. Olivo-Marin, Gaussian Approximations of Fluorescence Microscope Point-Spread Functions, Appl. Opt. 46, 1819 (2007).
  29. M. J. Nasse and J. C. Woehl, Realistic Modeling of the Illumination Point Spread Function in Confocal Scanning Optical Microscopy, J. Opt. Soc. Am. A 27, 295 (2010).
  30. J.-A. Conchello and J. W. Lichtman, Theoretical Analysis of a Rotating-Disk Partially Confocal Scanning Microscope, Appl. Opt. 33, 585 (1994).
  31. E. Dusch, T. Dorval, N. Vincent, M. Wachsmuth, and A. Genovesio, Three-Dimensional Point Spread Function Model for Line-Scanning Confocal Microscope with High-Aperture Objective, J. Microsc. 228, 132 (2007).
  32. R. Wolleschensky, B. Zimmermann, R. Ankerhold, and M. Kempe, High-Speed Scanning Confocal Microscope for the Life Sciences, in European Conference on Biomedical Optics 2005 (International Society for Optics and Photonics, 2005), pp. 58600N–58600N, http://dx.doi.org/10.1117/12.632957.
  33. E. J. Botcherby, M. J. Booth, R. Juškaitis, and T. Wilson, Real-Time Slit Scanning Microscopy in the Meridional Plane, Opt. Lett. 34, 1504 (2009).
  34. J. C. Crocker and D. G. Grier, Methods of Digital Video Microscopy for Colloidal Studies, J. Colloid Interface Sci. 179, 298 (1996).
  35. D. W. Marquardt, An Algorithm for Least-Squares Estimation of Nonlinear Parameters, J. Soc. Ind. Appl. Math. 11, 431 (1963).
  36. M. K. Transtrum, B. B. Machta, and J. P. Sethna, Why Are Nonlinear Fits to Data So Challenging?, Phys. Rev. Lett. 104, 060201 (2010).
  37. M. K. Transtrum, B. B. Machta, and J. P. Sethna, Geometry of Nonlinear Least Squares with Applications to Sloppy Models and Optimization, Phys. Rev. E 83, 036701 (2011).
  38. M. K. Transtrum and J. P. Sethna, Improvements to the Levenberg-Marquardt Algorithm for Nonlinear Least-Squares Minimization, arXiv:1201.5885.
  39. R. M. Neal, Slice Sampling, Ann. Stat. 31, 705 (2003).
  40. A. Einstein, On the Movement of Small Particles Suspended in Stationary Liquids Required by the Molecular-Kinetic Theory of Heat, Ann. Phys. (Berlin) 322, 549 (1905).
  41. D. B. Allan, T. A. Caswell, and N. C. Keim, Trackpy v0.2 (2014), http://soft-matter.github.io/trackpy/v0.3.2/.
  42. W. B. Russel, D. A. Saville, and W. R. Schowalter, Colloidal Dispersions (Cambridge University Press, Cambridge, England, 1989).
  43. J. N. Israelachvili, Intermolecular and Surface Forces, 3rd ed. (Academic Press, New York, 2011).
  44. J. N. Israelachvili and G. E. Adams, Measurement of Forces Between Two Mica Surfaces in Aqueous Electrolyte Solutions in the Range 0–100 nm, J. Chem. Soc., Faraday Trans. 1 74, 975 (1978).
  45. W. A. Ducker, T. J. Senden, and R. M. Pashley, Direct Measurement of Colloidal Forces Using an Atomic Force Microscope, Nature (London) 353, 239 (1991).
  46. D. C. Prieve, Measurement of Colloidal Forces with TIRM, Adv. Colloid Interface Sci. 82, 93 (1999).
  47. J. C. Crocker and D. G. Grier, Methods of Digital Video Microscopy for Colloidal Studies, J. Colloid Interface Sci. 179, 298 (1996).
  48. Source code available with documentation and tutorials at http://www.lassp.cornell.edu/sethna/peri/index.html.

  49. B. Ovryn and S. H. Izen, Imaging of Transparent Spheres through a Planar Interface Using a High-Numerical-Aperture Optical Microscope, J. Opt. Soc. Am. A 17, 1202 (2000).
  50. L. Reimer and H. Kohl, Transmission Electron Microscopy: Physics of Image Formation, 5th ed. (Springer, New York, 2008), Vol. 36.
  51. C. J. Chen, Introduction to Scanning Tunneling Microscopy (Oxford University Press on Demand, New York, 1993), Vol. 4.
  52. W. B. Russel, D. A. Saville, and W. R. Schowalter, Colloidal Dispersions (Cambridge University Press, Cambridge, England, 1989).

Outline

Information

Sign In to Your Journals Account

Filter

Filter

Article Lookup

Enter a citation