Export citation

Export citation

Choose format for download:

Download Citation

    Stabilization of Liner Implosions via a Dynamic Screw Pinch

    Paul C. Campbell1, T. M. Jones1, J. M. Woolstrum1, N. M. Jordan1, P. F. Schmit2, J. B. Greenly3, W. M. Potter3, E. S. Lavine3, B. R. Kusse3 et al.

    D. A. Hammer3 and R. D. McBride1

    • 1Nuclear Engineering and Radiological Sciences, University of Michigan, Ann Arbor, Michigan 48109, USA
    • 2Sandia National Laboratories, Albuquerque, New Mexico 87185, USA
    • 3Laboratory of Plasma Studies, Cornell University, Ithaca, New York 14853, USA

    Phys. Rev. Lett. 125, 035001 – Published 16 July, 2020

    DOI: https://doi.org/10.1103/PhysRevLett.125.035001

    Abstract

    Magnetically driven implosions are susceptible to magnetohydrodynamic instabilities, including the magneto-Rayleigh-Taylor instability (MRTI). To reduce MRTI growth in solid-metal liner implosions, the use of a dynamic screw pinch (DSP) has been proposed [P. F. Schmit et al., Phys. Rev. Lett. 117, 205001 (2016)]. In a DSP configuration, a helical return-current structure surrounds the liner, resulting in a helical magnetic field that drives the implosion. Here, we present the first experimental tests of a solid-metal liner implosion driven by a DSP. Using the 1-MA, 100–200-ns COBRA pulsed-power driver, we tested three DSP cases (with peak axial magnetic fields of 2 T, 14 T, and 20 T) and a standard z-pinch (SZP) case (with a straight return-current structure and thus zero axial field). The liners had an initial radius of 3.2 mm and were made from 650-nm-thick aluminum foil. Images collected during the experiments reveal that helical MRTI modes developed in the DSP cases, while nonhelical (azimuthally symmetric) MRTI modes developed in the SZP case. Additionally, the MRTI amplitudes for the 14-T and 20-T DSP cases were smaller than in the SZP case. Specifically, when the liner had imploded to half of its initial radius, the MRTI amplitudes for the SZP case and for the 14-T and 20-T DSP cases were, respectively, 1.1±0.3  mm, 0.7±0.2  mm, and 0.3±0.1  mm. Relative to the SZP, the stabilization obtained using the DSP agrees reasonably well with theoretical estimates.

    Physics Subject Headings (PhySH)

    Authorization Required

    We need you to provide your credentials before accessing this content.

    References (Subscription Required)

    Outline

    Information

    Sign In to Your Journals Account

    Filter

    Filter

    Article Lookup

    Enter a citation