    Origins of the intrinsic noise of zero-field metastable helium-4 optically pumped magnetometers

    Alexandre Stathopulos, Rudy Romain, Sergey Mitryukovskiy, and Agustin Palacios-Laloy*

    • Mag4Health, 6 place Robert Schuman, Grenoble, France

    • *Contact author: apl@mag4health.com

    Phys. Rev. A 114, 012619 – Published 22 July, 2026

    DOI: https://doi.org/10.1103/m7zt-mmr1

    Abstract

    We report a comprehensive characterization of the intrinsic noise of a single-beam He4-based vector optically pumped magnetometer, and identify its main origins. In its optimal regime, the sensor provided vector magnetic readings with noise below 30fT/Hz on two axes. We show that photon shot noise dominates at the optimum, and that the standard quantum limit set by spin projection of the aligned ensemble lies around 4fT/Hz. An extra noise is observed on one axis. It fits well with our model of metastable atom transit, suggesting interesting links with spin-noise spectroscopy.