Export citation

Export citation

Choose format for download:

Download Citation

    Quantum refrigerator embedded in spin-star environments: Scalings of temperature and refrigeration time

    Sukrut Mondkar*, Aparajita Bhattacharyya†, and Ujjwal Sen‡

    • Harish-Chandra Research Institute, Chhatnag Road, Jhunsi, Prayagraj 211 019, India and Homi Bhabha National Institute, Training School Complex, Anushakti Nagar, Mumbai 400 094, India

    • *Contact author: sukrutmondkar@hri.res.in
    • †Contact author: aparajitabhattacharyya@hri.res.in
    • ‡Contact author: ujjwal@hri.res.in

    Phys. Rev. A 114, 022202 – Published 5 August, 2026

    DOI: https://doi.org/10.1103/gmym-568h

    Abstract

    We examine a quantum absorption refrigerator that comprises three qubits, each of which is connected with a separate spin-star environment, with the three qubit-bath units coupled through an effective six-body interaction. The refrigerator exhibits the feature of transient cooling, i.e., lowering of the temperature of the first qubit in sufficiently small timescales, rather than steady-state refrigeration. A key advantage of our model is that the symmetries of the Hamiltonian enable a semianalytic solution of the reduced density matrices of the refrigerator qubits, even in the presence of a large number of environmental spins. We derive the condition for autonomous refrigeration and analyze how the optimal cold-qubit temperature scales with the number of bath spins. We find a power-law scaling toward a constant asymptotic value. We also find the scaling of the minimum time required for optimal cooling as a function of the number of bath spins. Furthermore, we quantify the non-Markovianity of the cold-qubit dynamics using a restricted Breuer-Laine-Piilo information-backflow measure and observe that stronger backflow correlates with lower transient minimum temperatures across the sampled parameter regime. The transient-cooling performance is found to be robust under broad parameter variations. Compared to a conventional Markovian three-qubit refrigerator, the central-spin quantum absorption refrigerator achieves lower cold-qubit temperatures on shorter timescales. We further analyze the heat currents associated with the three qubits and their respective baths.

    Physics Subject Headings (PhySH)

    Authorization Required

    We need you to provide your credentials before accessing this content.

    References (Subscription Required)

    Outline

    Information

    Sign In to Your Journals Account

    Filter

    Filter

    Article Lookup

    Enter a citation