Export citation

Export citation

Choose format for download:

Download Citation
  • Letter

Optimized observable readout from single-shot images of ultracold atoms via machine learning

Axel U. J. Lode1,*, Rui Lin2, Miriam Büttner1, Luca Papariello3, Camille Lévêque4,5, R. Chitra2, Marios C. Tsatsos6, Dieter Jaksch7,8, and Paolo Molignini7,9,†

  • 1Institute of Physics, Albert-Ludwig University of Freiburg, Hermann-Herder-Strasse 3, 79104 Freiburg, Germany
  • 2Institute for Theoretical Physics, ETH Zürich, 8093 Zurich, Switzerland
  • 3Research Studio Data Science, RSA FG, Thurngasse 8/16, 1090 Wien, Austria
  • 4Vienna Center for Quantum Science and Technology, Atominstitut, TU Wien, Stadionallee 2, 1020 Vienna, Austria
  • 5Wolfgang Pauli Institute c/o Faculty of Mathematics, University of Vienna, Oskar-Morgenstern Platz 1, 1090 Vienna, Austria
  • 6Honest AI Ltd., 65 Goswell Road, London EC1V 7EN, United Kingdom
  • 7Clarendon Laboratory, University of Oxford, Oxford OX1 3PU, United Kingdom
  • 8Institut für Laserphysik, Universität Hamburg, 22761 Hamburg, Germany
  • 9Cavendish Laboratory, 19 JJ Thomson Ave, Cambridge CB3 0HE, United Kingdom

  • *auj.lode@gmail.com
  • †phys2088@ox.ac.uk

Phys. Rev. A 104, L041301 – Published 8 October, 2021

DOI: https://doi.org/10.1103/PhysRevA.104.L041301

Abstract

Single-shot images are the standard readout of experiments with ultracold atoms, the imperfect reflection of their many-body physics. The efficient extraction of observables from single-shot images is thus crucial. Here we demonstrate how artificial neural networks can optimize this extraction. In contrast to standard averaging approaches, machine learning allows both one- and two-particle densities to be accurately obtained from a drastically reduced number of single-shot images. Quantum fluctuations and correlations are directly harnessed to obtain physical observables for bosons in a tilted double-well potential at an extreme accuracy. Strikingly, machine learning also enables a reliable extraction of momentum-space observables from real-space single-shot images and vice versa. With this technique, the reconfiguration of the experimental setup between in situ and time-of-flight imaging is required only once to obtain training data, thus potentially granting an outstanding reduction in resources.

Physics Subject Headings (PhySH)

Authorization Required

We need you to provide your credentials before accessing this content.

Supplemental Material (Subscription Required)

References (Subscription Required)

Outline

Information

Sign In to Your Journals Account

Filter

Filter

Article Lookup

Enter a citation