Export citation

Export citation

Choose format for download:

Download Citation

    Impact of rotation on a cold-atom interferometer and compensation strategy

    Noémie Marquet1,*, Yannick Bidel1, Malo Cadoret2, Alexis Bonnin1, Sylvain Schwartz1, Phuong-Anh Huynh3, Alexandre Bresson1, Antoine Godard4, Franck Pereira Dos Santos5 et al.

    Olivier Carraz6 and Nassim Zahzam1,†

    • 1DPHY, ONERA, Université Paris-Saclay, 91120 Palaiseau, France
    • 2LCM, CNAM, 93210 La Plaine Saint-Denis, France
    • 3DPHY, ONERA, Université Paris-Saclay, 92320 Châtillon, France
    • 4ONERA, Université Paris-Saclay, 91120 Palaiseau, France
    • 5Laboratoire Temps Espace, Observatoire de Paris, Université PSL, Sorbonne Université, Université de Lille, LNE, CNRS, 75014 Paris, France
    • 6ESTEC, ESA, 2201 AZ Noordwijk, The Netherlands

    • *Contact author: noemie.marquet@lkb.upmc.fr
    • †Contact author: nassim.zahzam@onera.fr

    Phys. Rev. A 113, 023316 – Published 18 February, 2026

    DOI: https://doi.org/10.1103/9gt6-bjl6

    Abstract

    Rotations play a detrimental role in achieving ultra-high-performance inertial measurements with an atom interferometer, leading potentially to a total loss of interference contrast and the emergence of dominant phase-shift biases. This becomes particularly significant when considering operation in dynamic conditions such as those encountered by Earth-orbiting satellites in the perspective of future space gravity missions onboarding a cold-atom accelerometer. In this context, we perform an experimental study of the impact of rotation on an atom interferometer and investigate mitigation strategies. Using an original setup in which the well-controlled proof mass of a space electrostatic accelerometer is used as the retroreflection mirror of a cold-atom gravimeter, we are able to measure both the contrast and phase shift of the interferometer especially for low and high angular accelerations. Thanks to an analytical model, we are able to explain the origin of the measured contrast loss and phase shifts arising from the different inertial accelerations. By properly counterrotating the electrostatic proof mass, we demonstrated a contrast, otherwise equal to zero, to a level better than 90%, for both constant angular velocities and for important angular accelerations. For constant angular velocities, our model retrieves the experimental data with an error of 25mrad, in agreement with the experimental uncertainty. Our results demonstrate the possibility to perform high-performance inertial measurements with a cold-atom interferometer in challenging environments by demonstrating a high contrast recovery and the precise determination of the rotation-induced phase-shift bias.

    Physics Subject Headings (PhySH)

    Authorization Required

    We need you to provide your credentials before accessing this content.

    References (Subscription Required)

    Outline

    Information

    Sign In to Your Journals Account

    Filter

    Filter

    Article Lookup

    Enter a citation